Installation
DiamondMax10 80/100/120/160/200/250/300GB AT 3-7
Once you install the CS jumper, the drive is configured as a Master or
Slave by the state of the Cable Select signal: pin 28 of the ATA bus
connector. Please note that pin 28 is a vendor-specific pin that Maxtor
is using for a specific purpose. More than one function is allocated to
CS, according to the ATA CAM specification (see reference to this
specification in Chapter 1). If pin 28 is a 0 (grounded), the drive is
configured as a Master. If it is a 1 (high), the drive is configured as a
Slave. In order to configure two drives in a Master/Slave relationship
using the CS jumper, you need to use a cable that provides the proper
signal level at pin 28 of the ATA bus connector. This allows two drives
to operate in a Master/Slave relationship according to the drive cable
placement.
The DiamondMax10 80/100/120/160/200/250/300GB AT hard disk
drives are shipped from the factory as a Master (Device 0 - CS jumper
installed). To configure a drive as a Slave (Device 1- DS scheme), the
CS jumper must be removed. In this configuration, the spare jumper
removed from the CS position may be stored on the PK jumper pins.
3.3.1.2 Drive Select (DS) Jumper
You can also daisy-chain two drives on the ATA bus interface by using
their Drive Select (DS) jumpers. To use the DS feature, the CS jumper
must not be installed.
To configure a drive as the Master (Device 0), a jumper must be installed
on the DS pins.
Note: The order in which drives are connected in a daisy chain
has no significance.
3.3.1.3 Master Jumper Configuration
In combination with the current DS or CS jumper settings, the Slave
Present (SP) jumper can be implemented if necessary as follows:
Note: The CS position doubles as the Slave present on this
drive.
When the drive is configured as a Master
(DS jumper installed
or CS jumper installed, and the Cable Select signal is set to
(0), adding an additional jumper (both jumpers DS and CS now
installed) will indicate to the drive that a Slave drive is
present. This Master with Slave Present jumper configuration
should be installed on the Master drive only if the Slave drive
does not use the Drive Active/Slave Present (DASP–) signal
to indicate its presence.